EnviR - Specifications
For more information on the data output of the EnviR, please see further
info HERE.
Viewable Screen: |
7.3cm x 9cm |
Retail Package Size: |
18.3cm x 6.8cm x 37cm |
Internal Power Requirement: |
Mains block power adaptor (less than 1 Watt) |
Physical Format: |
Table-top |
Energy Monitored: |
Electricity (gas, LPG, oil and water in development) |
Receiver: |
433MHz SRD band |
Communication Platform: |
C2 architecture |
Sensor Coding Recognition: |
10 channels |
Recognition Method: |
User Initiated - seeks 4,096 possibilities |
Number of Permitted Sensors: |
10 |
Display: |
Liquid Crystal segmented display |
Backlight: |
No |
LCD mode: |
Positive reflective -12:00 view |
Main services: |
Energy usage and current cost in £’s |
Subordinate Services: |
Room Temperature (0-29oC) |
WT Reception Licence Required: |
No |
Graphical representation of energy usage |
|
PC connection for streaming data for 10 channels |
|
Ability to receive accurate usage from utility meter |
|
Tariff pre-set at prevailing rate (issued by the purchaser) Adjustable to 99.9p |
|
NOTE: CT based devices are intended to offer an excellent guide to energy usage. They are not meant to be a replacement for a tariff meter, a smart meter or to check the accuracy of either and will offer the user an overall accuracy of >97% depending on the type of appliances in use. |
|
CE Approvals: |
ETSI EN 300 220-2 V2.1.1(2006-04), EN 50371 2002, EN 301489-3 v1.4.1 2002-08, EN 60215:1989+A1:1992+A2:1994, IEC 60950-1:2001(1st Edition) and/or EN 60950-1:2001+A11:2004 |